What You Are Learning
By the end of this lesson you will be able to use the word footage correctly in both of its linked meanings in outside plant fiber construction. First, footage is a length measured in feet, used for work quantities, span lengths, segment lengths, and records. Second, footage also refers to the sequential footage marks printed on a fiber cable jacket, and on some other cables, that let a crew record a start mark and an end mark and calculate the length between them by subtraction.
You will be able to explain where footage appears on construction information: as a plan quantity on a print, as a field measurement during installation, and as an as-built record after installation. You will be able to tell the difference between plan footage, which is what the design shows, and as-built footage, which is what was actually installed and recorded. You will be able to read a footage mark in the field, record marks at splices, coils, and cable ends, and use those records to calculate installed length, slack stored in a coil, and length remaining in a piece of cable. Finally, you will be able to state the limits: marking intervals and print formats vary by maker and by product, cable jacket footage is not the same as the exact optical fiber length inside the cable, and reading a mark never qualifies anyone to do regulated or hazardous work.
This lesson follows Lesson 78, which covered offset. Offset tells you how far a feature sits from a reference line. Footage tells you how much length there is along a run. Lesson 80, which covers profile, will show length and elevation together in a side view.
Start With the Basics
Start with the plain unit. A foot is a unit of length. In the United States customary system used on most domestic outside plant prints, distances and lengths are commonly stated in feet, sometimes with decimal parts of a foot and sometimes with feet and inches. The word footage means a length expressed in feet. If a print note says a conduit run has a footage of 645, it means that run is 645 feet long, unless the print states a different unit.
Define three related words before going further, because this lesson uses all three constantly.
A quantity is an amount of work or material counted in a stated unit. On outside plant work, common quantity units include each, for countable items such as handholes, and feet, for length based items such as conduit, duct, cable, and bore runs. A footage quantity is a quantity counted in feet.
A span is the section of a route between two defined points, such as two poles, two handholes, or a pole and a building. A segment is a similar word for a section between two points, often used for underground runs and cable sections. Both spans and segments have a footage: the length of that section along its path.
A record is a written note of a fact made at the time the fact was observed. In this lesson, the key records are numbers copied off a cable jacket in the field. A number remembered at the end of the day is not the same as a number recorded at the splice, the coil, or the cut.
Now the second meaning. Many fiber cables carry printed text that repeats along the outer jacket, the protective outer covering of the cable. Part of that text is a number that changes in sequence as you move along the cable. That number is a footage mark when the cable is printed in feet, or a meter mark when the cable is printed in meters. Corning, a major fiber cable maker, defines meter and foot marks in its glossary as the distance markings stamped on the cable jacket by the factory in either meters or feet. The marks count along the length of the cable, so two marks read at two points on the same cable let you calculate the length of cable between those points.
Hold the link between the two meanings. Footage the quantity is a length in feet. Footage marks are the factory printed numbers on the cable that let you measure and record that length in the field without unrolling a tape along the whole run.
This lesson teaches recognizing, reading, and recording footage. It does not qualify anyone to pull cable, open splice closures, enter underground structures, or perform any other regulated or hazardous task. Those jobs have their own training, authorization, and safety requirements.
What Is It?
Footage, in its first sense, is any length in outside plant work stated in feet. It is how prints state the length of a route, a span, a bore, a conduit run, and a cable section. It is how work is often counted for progress and, where the contract uses unit prices for length based items, how completed work is counted for payment. The contract documents for a specific project state how quantities are measured and paid for on that project. Never assume a payment rule from this lesson. Read the contract and the project specifications.
Footage, in its second sense, is the sequential numbering printed on a cable jacket. A footage mark is one printed value in that sequence. Reading from one end of a continuous piece of cable to the other, the values step up or step down in a regular sequence. Which direction the numbers run depends on which end of the piece you start from and how that maker printed that cable. The direction does not change the math. The length between two points on the same continuous piece is the difference between the two marks at those points: the larger value minus the smaller value.
Three facts about the marks matter for every reader.
First, a footage mark is not a location. A mark of 12,480 does not mean the cable is 12,480 feet from the start of your project, from a building, or from any landmark. It means that point on the cable sits at that value in the factory sequence for that piece of cable. A piece cut from the middle of a long factory length will start and end in the middle of the sequence, and that is normal. The Fiber Optic Association, usually shortened to FOA, illustrates this with a cable reading 00030 FEET near one end of a section. The useful fact is not the number by itself. The useful fact is the pair: this mark here, and the mark at the other end or at the far point you care about.
Second, the marks are a property of a specific cable product from a specific maker. The unit, the step between printed values, the direction of the sequence, and the rest of the print line all come from that maker for that product. Corning generic specifications for several of its cable families call for sequential length markings every two feet for cables marked in feet, or every one meter for cables marked in meters. That two foot step is a Corning specification for those products, documented in the Sources section. It is not a universal rule for all fiber cable. CommScope catalog material treats jacket marking as an ordering choice, with sequentially marked in feet as its standard option and sequentially marked in meters as another option. Prysmian ordering material likewise shows cables printed in feet as a configured option. So the correct field habit is: read the actual cable in your hands and check the maker data sheet for that exact product if the step or the unit matters. Do not carry a step, a unit, or a print format from one cable to the next job.
Third, not every cable and not every length carries usable marks. A legible mark may not be available at a given point: marks can be worn, dirty, faded, damaged, or hidden inside a duct, a coil, or a closure. Where no legible mark exists at a point, the crew needs another approved way to establish length for that point, such as measuring the section by a method the project accepts, and the record should say how the length was established. A missing mark is never a reason to invent a number.
Footage also needs one more distinction that runs through the rest of this level. Plan footage is the length shown in the design, worked out from the route, the stationing, and the geometry on the prints. As-built footage is the length recorded after the work was actually placed, including the real path taken, the slack left at structures, and the cable used at splices and ends. The two numbers are related, and they are often close, and they are not automatically the same number. The difference between them is information, not an embarrassment to hide. Later sections explain why they differ and why both are kept.
What Does It Look Like?
On a print, footage looks like numbers attached to the work. A plan sheet may label a run with its length in feet next to the line that represents the conduit or cable. A quantity table or a sheet summary may list footage totals by item, by sheet, or by segment. A splice diagram or cable schematic may show a cable section with its planned length. The exact layout belongs to that drawing set, and Lesson 75 covered the legend that defines the symbols and line types, while earlier lessons in this level covered the title block, the stationing, and the offset information that place those numbers on the ground. When you see a bare number near a run, confirm from the sheet notes and the legend whether it is a length, a station, an offset, or something else before you use it. Numbers on prints only mean what that set defines them to mean.
In the field, footage looks like print on a cable. Walk up to an exposed fiber cable at a reel, a handhole, a pole, or a splice point, where you are authorized to be, and look along the jacket. The print line repeats along the cable. A typical print line includes the maker name, a product or cable description, the fiber count and fiber type, the date or year of manufacture in some format, and then the sequential length value followed by the unit word, such as FEET or a meter unit on metric printed cable. Corning specifications describe the marking as printed in a contrasting color to the cable jacket, so the text stands out against the jacket color. On black outside plant jacket, the print is commonly a light color. The exact wording, order, and letter size vary by maker and product.
Read a single mark carefully. The value is a sequence number, often shown with leading zeros, such as 012480 FEET. The leading zeros are part of how the maker prints the sequence. They do not change the value. Twelve thousand four hundred eighty is the number, however many zeros pad the front of it.
Move a short distance along the same cable and read again. The maker name and product text repeat, and the number has changed by a small, regular step. On the Corning products described above, that step is two feet between printed values, so consecutive print lines differ by two. On another maker product the step can differ. If the values you read do not change in a steady step, stop and consider the ordinary explanations first: dirt over part of a digit, a worn print line, a misread digit, or a different cable than the one you thought you were following. In a handhole or at a pole, several cables can sit side by side, and each cable has its own jacket print and its own sequence. Marks from two different cables must never be combined in one calculation.
At a reel, footage has one more visible form. Where reel labels or packing paperwork for a shipment state the cable description, the length shipped, or the start and end marks for the piece on the reel, those records let the office and the crew cross check the jacket marks against the shipped record before and after a pull. The paperwork format is the maker and supplier format for that shipment, not a universal form.
At a splice point or a coil, footage looks like two records, not one. A cable entering a closure or a coil has a mark where it enters, and the same cable leaving has a different mark where it leaves. The pair of marks is what the next section uses. If you only ever notice the print as background text on the jacket, you are missing the working tool. In the field, a footage mark is a measurement waiting to be recorded at a specific point, with the location and the cable identified next to it.

What Does It Do?
Footage does five jobs in outside plant construction.
First, plan footage sizes the work. Designers use the lengths on the prints to order cable, duct, and conduit, to plan reel lengths and pull lengths, to lay out splice points, and to estimate the quantities the contract will be measured against. A cable section planned between two splice points needs a piece of cable at least as long as the path between them, plus the allowances the design and the project specifications require for splicing, coiling, and termination work. Those allowances come from the project documents and the maker instructions, not from this lesson, and no allowance value is stated here because no single value applies to all projects.
Second, footage marks let a crew calculate installed cable length without measuring the whole buried or aerial path. The crew records the mark at the start of a section and the mark at the end of that section. Subtracting the smaller from the larger gives the feet of cable between those two points. The FOA cable reading reference makes exactly this point: knowing the mark at one end and the mark at the other end of a section lets installers keep track of how much cable was used. The same subtraction, applied to the two ends of a piece left on a reel or in storage, gives the length remaining in that piece, provided both marks are on that same continuous piece and both are read correctly.
Third, footage marks account for slack. Slack is extra cable deliberately left at a structure, in a handhole, at a pole, or in a splice location, so the cable can be spliced, re-entered, repaired, or moved later without adding a new piece. A coil of slack is real cable that was pulled and paid for as material, and it sits between the mark where the cable enters the coil and the mark where it leaves. Subtracting that pair tells the next crew exactly how much cable is stored there. Without that record, a later crew cannot tell a generous coil from a short tail without opening and disturbing the work.
Fourth, footage records help locate a point later. Test instruments and splice records are tied to lengths along the cable. When a splice record lists the footage marks at a closure, and a later test result points to a distance along the fiber, the marks give the maintenance crew a physical reference for relating that distance to the actual cable in the ground or on the poles. The marks do not replace test equipment, locates, or project records. They connect those records to a real, readable point on the jacket.
Fifth, as-built footage closes the loop on the job. The recorded marks at splices, structures, coils, and ends become part of the as-built documentation, the corrected record of what was actually built. That record supports final quantities where the contract measures work that way, supports acceptance review by the owner or the authorized inspector, and becomes the starting point for every repair and upgrade crew that follows. Formal acceptance belongs to the owner or the authorized party, not to the person who recorded the marks. The recorder job is to make the record accurate, legible, and complete enough for that review to happen.
Notice what footage does not do. A jacket mark does not tell you the exact length of the glass fiber inside the cable. FOA testing guidance notes that the fiber inside a cable is usually a small percentage longer than the cable itself, because the fibers are not laid perfectly straight inside the cable construction. So a distance reported by an optical test instrument, which measures along the fiber, and a length calculated from jacket marks, which measure along the cable, are related but are not expected to match to the foot. A difference between them is normal physics, not proof that either record is wrong. Corning loose tube specifications state a marking accuracy for their own products, for example that the actual length of the cable shall be within a stated small percentage band of the length markings on the products covered by that specification. That kind of tolerance statement is maker and product specific. Check the data sheet for the cable actually installed before you judge any comparison.
Where Does It Fit?
Footage fits everywhere length is planned, installed, or remembered, which in outside plant work is nearly everywhere.
It fits in this level in sequence. Lesson 72 introduced the construction print. Lesson 74 covered the plan sheet, the top down view. Lessons on stationing and offset taught you to place a point: stationing places it along the route, and offset places it to the side of a reference line. Footage answers the next question about any section between two placed points: how long is it, how much cable went into it, and how much is left. Lesson 80 will add the side view in profile, where the same lengths appear with elevation, and the footage along a profile still has to agree with the footage on the plan and in the field records.
It fits at the design desk, where route lengths become plan quantities, cable orders, and splice layouts. It fits in the warehouse and the yard, where reel paperwork and end marks decide which piece of cable goes to which section, and whether a remaining piece is long enough for a planned run. It fits in the field during the pull or the aerial placement, where start and end marks are recorded at each structure and splice. It fits at splicing, where the marks at each closure are entered on the splice record for that closure. And it fits in the office after construction, where as-built footage is drawn onto the record prints and entered into the owner records and mapping systems that later crews will trust.
It also fits next to, but separate from, two things it is often confused with. It is separate from stationing. A station is a position along the designed route measured from a route reference point. A footage mark is a position along a piece of cable measured in the factory sequence. The two systems both use feet, and on a given section their numbers can even be close, but they measure different things from different starting points. Never copy a station value into a cable record, or a jacket mark onto a print as if it were a station. It is also separate from a locate. A locate marks where buried facilities are on the ground for digging protection. A footage mark is printed on one cable. Knowing the footage at a handhole does not tell you where it is safe to dig, and this lesson is not a substitute for the locate process covered elsewhere in this curriculum.
Why Does It Matter?
It matters first because cable is ordered, cut, and paid for by length. If plan footage is read carelessly, the wrong reel lengths get ordered, a pull comes up short before the far structure, or a long and expensive piece is cut where a shorter remaining piece would have served. If field footage is recorded carelessly, the error is worse, because it is discovered later, by a different crew, at the moment they are counting on the record.
It matters because slack is invisible without footage. A coil in a handhole looks like a coil. Whether it holds a short tail or a long, usable length of spare cable is a fact that only the entry and exit marks state precisely. Repair work after storm damage, a vehicle strike on a pole, or a dig in all move faster when the records say how much cable is stored at each point. They move slower, and sometimes stop, when the answer is a guess.
It matters because as-built footage is part of how the owner knows what it owns. The network that gets operated for decades is the network described in the records, not the network described in the original design. Where the built path differs from the planned path, where a splice moved, where extra slack was left, the as-built footage is what keeps the record honest. Inspectors verify records against the field, and a footage record that cannot be reproduced by reading the jacket at the stated points fails that check on its face.
It matters because footage errors compound quietly. One transposed digit in a start mark shifts every length calculated from it. One pair of marks taken from two different cables in the same handhole produces a length that belongs to no real cable at all. One record that mixes meters from a metric printed cable into a feet based record produces a section that is wrong by more than a factor of three, with no obvious sign of the error on the page. These are not exotic failures. They are copying and reading failures, and they are prevented by the habits in the next two sections.
Finally, it matters because footage is one of the few measurements a beginner can verify personally. You do not need an instrument to read two marks, subtract them, and check that the result makes sense against the distance between the two structures on the print. That habit, checking one record against another independent fact, is the core inspection habit for all of outside plant work, and footage is where many people learn it first.
What Does Good Look Like?
Good footage practice is a short discipline repeated at every point where cable is cut, spliced, coiled, or stored.
Good looks like identifying the cable before reading the mark. The record states which cable it is, using the project cable name or identifier, and where the reading was taken, such as a named handhole, pole, or closure. A bare number with no cable and no location is not a record. It is a rumor with digits.
Good looks like reading the full print line, not just the number. The reader confirms the unit word after the value, feet or meters, and confirms the print line belongs to the cable being recorded, including its fiber count and product description where the project records require it. If the cable is printed in meters, the record is kept in meters or converted by the method the project specifies, and the unit is written next to every value either way. A number without a unit is incomplete.
Good looks like recording both ends, every time. At a splice, the marks of each cable entering the closure are recorded. At a coil, the entry and exit marks are recorded. At a cut, the mark at the cut is recorded for both the installed piece and the piece going back to storage, along with the reel or piece identifier for the stored piece. A single ended record can never be turned into a length later.
Good looks like doing the subtraction in the field and sanity checking it on the spot. Installed length equals the larger mark minus the smaller mark. The result is compared, right there, with the plan footage for that section and with the obvious physical facts: the number of spans crossed, the distance between structures. A calculated length that is wildly different from the plan and the ground is investigated before the crew leaves the structure, while the jacket is still in front of them. Small differences have ordinary causes, including slack, vertical runs up poles, routing inside structures, and the designed path differing slightly from a straight line between points. Large differences have causes too, and they are cheaper to find today than next month.
Good looks like clean handling of the sequence direction. If the marks decrease in the direction the cable was placed, the recorder still records the actual values as printed, in the order encountered, and the length is still the difference between them. Nobody rewrites a printed value to make a record look tidier. The record shows what the jacket says.
Good also looks like legibility discipline. Marks are copied digit by digit, read back against the jacket, and written in the project record format at the time of the work. Where a mark is partly worn or dirty, the cable is cleaned or the nearest fully legible mark is read and its position relative to the point is noted, following the project practice. Where a value cannot be read with confidence, the record says so plainly. An honest note that a mark was illegible protects the next crew. A confident guess endangers them.
What Can Go Wrong?
The first failure is the single mark record: a crew records the mark at one end of a section and never records the other. No length can be calculated, no remaining footage can be proven, and the next crew has to treat the section as unmeasured. It happens most often at the end of a long day, which is exactly when the second reading matters most.
A second failure is mixing cables. In a crowded handhole or a multi cable closure, a reader takes the start mark from one cable and the end mark from another cable that happens to sit next to it. The subtraction produces a precise looking, completely false length. Identifying the cable by its full print line and tracing the same cable through the structure before reading is the prevention.
A third failure is mixing units. A metric printed cable read into a feet based record, or a conversion done from memory and never labeled, corrupts the section length and every total built on it. The unit word on the jacket is part of the reading. If it is not recorded, the reading is not finished.
A fourth failure is the transposed or dropped digit. Jacket values run to five or six digits. Copying 13,125 as 13,215 changes a section length by 90 feet and can make a stored coil appear to hold cable it does not hold, or make a remaining piece look long enough for a run it cannot serve. Reading the value back against the jacket, digit by digit, is a ten second check that prevents a failure measured in truck rolls.
A fifth failure is treating plan footage as as-built footage. A completion record copied from the print, instead of recorded from the jacket, hides every field change: the shifted splice, the added coil, the rerouted section. The job can look perfect on paper while the records describe a network that was never built. When verification later compares the record to the jacket, the mismatch discredits the whole record set, including the parts that were honest.
A sixth failure is assuming every cable works like the last one. A reader who assumes a two foot step, a feet unit, or an increasing sequence because the previous job cable had them will misread a cable that differs in any of those properties. The maker data for the actual product, and the print line actually on the jacket, are the authorities.
A seventh failure is physical: marks lost to damage. A jacket crushed, cut, burned, or worn at exactly the point where a record is needed leaves a gap that no arithmetic can fill. That is one reason records are taken at several points along a section, at every structure and splice, rather than only at the two far ends. Redundant records at intermediate points let a later crew reconstruct a section length even when one point is damaged.
None of these failures requires bad intent. They require only hurry. The countermeasure is procedural: identify the cable, read the full line, record both ends with units, subtract and sanity check in the field, and flag what could not be read.
What Should Someone Notice in the Field?
Use this section as a noticing guide wherever cable is exposed and you are authorized to observe the work. Noticing is not authorization. Do not open closures, enter structures, handle cable, or disturb any installation unless you are trained, equipped, and authorized for that task. Your job as a reader of construction information is to recognize the marks, check the records, and raise questions through the project process.
Notice the print line itself. Can you find the repeating jacket print on an exposed cable? Can you read the maker, the cable description, the fiber count, and the sequential value with its unit? If the print is there but you cannot read the value, notice that fact. Illegible print at a splice or storage point is a records problem worth reporting, not a detail to shrug off.
Notice whether the values step steadily. Read two consecutive print lines on the same cable. Do they differ by a small, regular step? That confirms you are following one continuous cable and gives you a feel for that product step. If the step jumps wildly between nearby lines on what should be one cable, you may be looking at two cables, a damaged section, or a misread digit.
Notice the pairs at structures. At a handhole, a pole coil, or a closure you are authorized to observe, is there a record for the marks entering and leaving? A structure with cable passing through it and no footage record is a gap in the as-built chain, and gaps are found cheapest at the moment the work is open.
Notice slack with numbers attached. A coil with recorded entry and exit marks is accounted slack. A coil with no record is unknown slack. Learn to see the difference, and learn to ask for the record rather than estimating coil length by eye.
Notice units everywhere. Check the unit word on the jacket against the unit used in the project records. Check that every footage value on a record, a print note, and a splice sheet carries or clearly inherits a stated unit. Mixed unit paperwork is one of the most reliable early warnings of a troubled record set.
Notice reel and remnant discipline. On a reel or a stored remnant, are the end marks and the piece length recorded where the next crew can find them, on the reel tag, the remnant tag, or the project record? A remnant with no recorded length will be measured again or ignored, and both outcomes waste the value stored in it.
Notice agreement between paper and ground. Compare a section plan footage with the field calculated footage when both are available to you. Small, explainable differences build confidence in both records. A large difference, in either direction, is a question to raise with specifics: the section, the plan value, the two jacket marks, and the calculated value. Specific questions get answers. Vague unease does not.
Practical Example
The following example is hypothetical. The place names, the marks, and the lengths are invented for teaching, and the arithmetic is shown in full so you can check it.
Hypothetical situation: A crew places one fiber cable from splice case A, through one handhole with a slack coil, to splice case B. The cable is printed in feet. The recorder identifies the cable by its full print line at each point and records the following marks, in the order the cable was placed:
- At splice case A, the mark on the cable is 12,480 FEET.
- At the handhole, the mark where the cable enters the slack coil is 13,020 FEET.
- At the handhole, the mark where the cable leaves the slack coil is 13,060 FEET.
- At splice case B, the mark on the cable is 13,125 FEET.
First calculation, the slack in the handhole coil. Use the pair of marks that brackets only the coil, the entry mark and the exit mark, and subtract the entry mark from the exit mark: 13,060 minus 13,020 equals 40. There are 40 feet of cable stored in that coil. Note why the pairing matters: subtracting any other pair would span more than the coil and would answer a different question.
Second calculation, the total cable from case A to case B. Subtract the start mark from the end mark: 13,125 minus 12,480 equals 645. There are 645 feet of cable between case A and case B, including the coil.
Third calculation, the cable in the pathway itself, excluding the stored slack. Subtract the coil from the total: 645 minus 40 equals 605. So 605 feet of the cable lies along the path between the two cases, and 40 feet is stored in the handhole. The two parts add back to the total: 605 plus 40 equals 645. The record checks against itself.
Now the sanity check the crew does in the field. The plan footage for the section from case A to case B on the print is 600 feet for the pathway. The field pathway figure is 605 feet. The difference is 5 feet, which the crew can account for from the routing through the structures and the riser runs at each end, as observed on site in this hypothetical example. The numbers are close, the difference is explainable, and the record is accepted by the crew lead for the project record, subject to the owner review process for that project.
Contrast one error, still in this hypothetical example. If the recorder had copied the case B mark as 13,215 instead of 13,125, the total would have calculated as 13,215 minus 12,480 equals 735 feet, a 90 foot error from one swapped pair of digits. Against a 600 foot plan section, that result should have failed the sanity check on the spot and sent the recorder back to the jacket for a digit by digit re-read. That is the whole method in one story: identify the cable, record both ends with the unit, subtract the correct pair, and check the answer against the plan and the ground before leaving the structure.
Key Terms
Footage: a length stated in feet. Also used for the sequential length numbering on a cable, as in footage marks. The context and the unit stated on the print or the jacket tell you which use is meant, and in practice the two uses work together.
Footage mark: one printed sequential length value on a cable jacket, followed by its unit, such as FEET. Also called a foot mark when printed in feet, or a meter mark when printed in meters.
Sequential marking: factory printing on a cable jacket in which the length value changes in a regular step along the cable, so the difference between two values gives the length between those points.
Jacket: the outer protective covering of a cable. The jacket carries the printed cable description and the sequential length marks.
Quantity: an amount of work or material counted in a stated unit, such as each for structures or feet for conduit, duct, cable, and bore runs.
Span: a section of a route between two defined points, such as two poles or two handholes. Each span has a length that can be stated as footage.
Slack: extra cable deliberately left at a structure, pole, or splice point for future splicing, repair, or re-entry. The entry and exit footage marks at a coil state how much slack is stored there.
Plan footage: the length for a section as shown in the design on the construction prints, before or independent of field measurement.
As-built footage: the length for a section as actually installed and recorded in the field, including the real path, slack, and end allowances as placed. As-built records are the corrected record of what was built.
Remnant: a remaining piece of cable, on a reel or in storage, after part of the original piece has been used. Its end marks state its remaining length.
Splice record: the project record for a splice location, which commonly includes the identity of each cable entering the closure and the footage marks at that closure, in the format the project specifies.
Check Your Understanding
- A cable mark reads 08,240 FEET at one end of a section and 08,890 FEET at the other end of the same section, on the same cable. How many feet of cable are between those two points, and how did you get the answer?
- A record lists a section length with no unit, taken from a cable printed in meters, and the value was entered into a feet based record set. Name two things wrong with that record.
- What is the difference between plan footage and as-built footage, and why are both kept?
- A coil in a handhole has no footage record. A second coil in the next handhole has entry and exit marks recorded. Which coil holds a known amount of slack, and why can the first coil length not simply be estimated by eye for the record?
- True or false, and explain: if the jacket marks on a cable step every two feet, that proves all fiber cables are marked every two feet.
Answer key:
- 650 feet. Subtract the smaller mark from the larger mark: 08,890 minus 08,240 equals 650. Both marks must be on the same continuous cable for the subtraction to be valid.
- First, the unit is missing, so the number is incomplete and can be mistaken for feet. Second, a value measured in meters was placed in a feet based record without a labeled conversion by the project method, which corrupts the section length and every total built on it. The unit word on the jacket is part of the reading and must be recorded with the value.
- Plan footage is the length shown in the design on the prints. As-built footage is the length actually installed and recorded from the field, including the real path taken, slack left at structures, and end allowances as placed. Both are kept because the plan shows what was intended and supports ordering and layout, while the as-built shows what the owner actually has, supports final quantity review where the contract measures that way, and is the record later crews rely on.
- The second coil. Its entry and exit marks subtract to a stated slack length that any later crew can reproduce by reading the same jacket points. The first coil has no such pair, and an eye estimate cannot be verified against the jacket after the structure is closed. A record must be reproducible from stated points, not based on an impression.
- False. A two foot step is documented in Corning generic specifications for specific Corning cable families. Other makers and other products can use different steps and different units, including meters. CommScope, for example, treats feet marking and meter marking as ordering options. The step, the unit, and the print format must be confirmed from the actual cable and its maker data every time.
Lesson Takeaway
Footage is length in feet, and footage marks are the factory numbers on the cable jacket that let you prove that length in the field. Read the full print line, identify the cable, record the marks at both ends of every section, coil, and cut, with the unit, and subtract the pair to get the length. Check the result against the plan and the ground before you leave the structure. Keep plan footage and as-built footage separate and honest. Do that, and a number written today will still be true, and still be checkable, for the crew that opens that structure years from now.
Sources and Technical References
Fiber Optic Association (FOA), Reading the Markings on Fiber Optic Cables. Defines the information printed on a cable jacket and states that the example cable distance marking, 00030 FEET, is updated every 2 feet on that cable, and that knowing the mark on the reel or at the other end lets installers track how much cable was used and how much was left. https://www.thefoa.org/tech/ref/cable/ReadingCables.html
Corning, Glossary of Terms, Meter/Foot Marks entry. Defines meter and foot marks as the distance markings stamped on the cable jacket by the factory in either meters or feet. http://www.corning.com/emea/en/products/communication-networks/resources/glossary-of-terms.html
Corning Optical Communications, Generic Specification for Loose Tube Ribbonized Optical Fiber Cables for Outdoor Applications, PGS030, September 2017, Revision 13. States that cable jackets shall be marked with sequential meter or foot markings, states a marking accuracy band for the products covered, and specifies sequential length markings every two feet in its jacket printing section. Product and maker specific. Not a universal requirement. https://www.corning.com/catalog/coc/documents/generic-specifications/PGS030.pdf
Corning Optical Communications, Generic Specification PGS029, September 2017, Revision 18. States sequential length markings every two feet for the cable family covered, with an example print line ending in FEET. Product and maker specific. https://www.corning.com/catalog/coc/documents/generic-specifications/PGS029.pdf
Electrical Contractor Magazine, Reading a Fiber Optic Cable, republishing the FOA cable reading material. Same 00030 FEET example, updated every 2 feet on that cable, used here as a second publication of the FOA source. https://www.ecmag.com/magazine/articles/article-detail/’reading’-a-fiber-optic-cable
CommScope, Fiber Optic Cable Products catalog, Cable Marking position in the catalog numbering key. Lists jacket sequentially marked in feet as the standard marking option and jacket sequentially marked in meters as another option, showing that unit is a configured product choice, not a single industry wide default. https://www.pro-saf.si/images/file/BroadbandCatalogFiberOptic_0108.pdf
Prysmian Group, Fiber Code Addendum, TLS-0008-0321. Ordering material showing a configured cable example described as printed in feet, with length markings as the first element of the ordering code. Used here only to support the point that print unit is a product configuration. https://na.prysmian.com/sites/na.prysmian.com/files/media/documents/TLS-0008-0321_Fiber%20Code%20Addendum.pdf
Fiber Optic Association (FOA), FOA Guide, Quickstart Guide to Fiber Optic Testing with OTDRs. Notes that the fiber is usually 1 to 2 percent longer than the cable, which is why optical test distances and jacket footage lengths are related but not identical. https://www.thefoa.org/tech/ref/quickstart/OTDR.html
United States Code of Federal Regulations, 7 CFR 1755.902, Minimum Performance Specification for Fiber Optic Cables, Identification Markers section. A federal specification example, written for its own program, requiring permanent cable identification, sequentially numbered length markers in meters or feet at regular intervals of not more than 2 feet or not more than 1 meter, and agreement between the actual length of the cable and the length marking within plus 1 percent and minus 0 percent. Cited as an example of a specification level requirement. It does not set the marking practice for commercial projects outside that program. https://www.govregs.com/regulations/title7_chapterXVII_part1755_section1755.902
Flagged as general practice, not verified to a single universal source: recording footage marks at splices, coils, and reel ends on splice records and as-built documents, and measuring contract quantities from as-built footage, are common project practices in outside plant work. No single universal standard mandating one record format was verified for this lesson. The governing format, the required record points, and the quantity measurement and payment method for any real section come from that project contract, its specifications, and the owner standards for that job. Verify them there before relying on them.
Flagged as unverifiable as a universal claim, and therefore not stated as a rule anywhere in this lesson: a universal marking interval for all fiber cable, a universal direction for the numbering sequence, and a universal marking accuracy tolerance. Each was verified only for specific maker products, as cited above, and each varies by maker and product.
Previous lesson: Lesson 78: What Is an Offset? |
Back to Level 4 hub |
Next lesson: Lesson 80: What Is a Profile?
